對于HFO-1234yf系統(tǒng),必須進行制冷劑識別。只有當
制冷劑高于98%,允許回收。
請注意,在開始此操作之前,清空舊油罐。
執(zhí)行沖洗功能是為了從空調系統(tǒng)中完全抽出壓縮機油,從而使污染物
作為酸化物質,水分和其他外來顆粒也會與油一起被提取出來。
沖洗過程中,制冷劑向前流動(將液態(tài)制冷劑從空調低壓側加注到
溶解壓縮機油,同時從高壓側恢復)和反向(反向
表示從高壓側充電,從低壓側恢復,與正??照{流量相反),每個方向
持續(xù)一段時間。沖洗時間可根據(jù)系統(tǒng)中的制冷劑量進行設置。對于
例如,使用500g制冷劑的空調系統(tǒng),建議將沖洗時間設置為30分鐘,而60分鐘
可為含有1kg或以上制冷劑的系統(tǒng)設置。沖洗制冷劑將被回收和凈化
在沖洗過程結束時自動儲存在儲液罐中,以備再次使用。
對于一些配備蒸發(fā)器電磁閥或電子膨脹閥的空調系統(tǒng),通常
當車輛空調關閉時,建議使用適當?shù)?br />或使用適當?shù)臉蚪优浼鹣虏蚪舆@些閥門。未執(zhí)行
如上所述,制冷劑流量受到限制,沖洗效率可能會受到影響。
對于多流冷凝器,冷凝器中的油可能無法完全沖洗干凈。
請確保設備中至少有3.5KG制冷劑,否則不允許進行沖洗。


JANCD-MSV01-485971
For the HFO-1234yf system, refrigerant identification is necessarily processed. Only when the purity of refrigerant is above 98% the recovery is allowed. Please note, empty used oil vessel before starting this operation. Flushing function is performed to completely extract compressor oil from the A/C system, thus contaminants such as acidified substances, moisture, and other foreign particles will also be extracted together with oil. During the flush, the refrigerant flows in the forward direction (charge liquid refrigerant from A/C low side to dissolve compressor oil, and at the same time recover from the high side) and reverse direction (reverse direction means charge from the high side and recover from the low side, in reverse from normal A/C flow), each direction lasts a certain period of time. Flush time can be set corresponding to the refrigerant amount in the system. For example, A/C system with 500g refrigerant, flush time is recommended to be set at 30 minutes, while 60 minutes can be set for the system with 1kg or more refrigerant. Flushing refrigerant will be recovered and purified automatically, at the end of the flushing process, and stored in the storage cylinder, ready for re-use. For some A/C systems equipped with evaporator solenoids or electronic expansion valves, which are normally closed when the vehicle A/C is off, it is recommended to activate the solenoid and TX valves with the proper diagnostic scanner or remove and bridge these valves with the appropriate bridging fittings. Not performing the above, refrigerant flow is restricted and flushing efficiency can be affected. For a multi-flow condenser, the oil in the condenser may not be flushed out completely. Please make sure at least 3.5KG refrigerant in equipment, or flush is not permitted to run.